Liquidtight Flexible Steel Conduit U.L. and CSA

TYPE - ATLA

Contact your local Sales Representative
Click Here for Printable Version

CartonFootageReelFootageList
Price
Trade
Size
TypeInside
Bend
Radius
Wt.
(Lbs.)/
100 Ft.
LengthPart #LengthPart #LengthPart #Price Per
100 FT
3/8"ATLA-102.0"291008020150080203100080204 $452.00
1/2"ATLA-113.0"321008021150080213100080214$521.00
3/4"ATLA-124.2"531008022150080224100080225$695.00
1"ATLA-135.5"821008023240080234--$1,049.00
1-1/4"ATLA147.0"102508024220080244--$1,457.00
1-1/2"ATLA-154.5"124508025215080254--$1,545.00
2"ATLA-166.0"145508026210080264--$1,968.00
2-1/2"ATLA-178.0"1922580272----$3,447.00
3"ATLA-1810.0"2522580282----$4,786.00
3-1/2"ATLA-35011.0"3082580288----$5,920.00
4"ATLA-1912.0"3502580292----$6,911.00

See Chart for Dimensions and Tolerances.



TYPE - ATLA
A liquidtight flexible steel conduit designed specifically for extreme hot or cold environments. The flexible inner core is identical to that found in Type LA. The specially formulated PVC jacket remains flexible at low temperatures and resists aging at elevated temperatures. It is listed by Underwriters Laboratories Inc. and certified by Canadian Standards Association

CONSTRUCTION:
ATLA has a flexible inner core made from a spiral wound strip of heavy gauge, hot-dipped galvanized steel. The 3/8 through 1-1/4 inch trade sizes contain an integral bonding strip of copper. The 1-1/2 inch and larger are designed with a fully interlocked strip.

The jacketing material is a rugged flame retardant flexible PVC resistant to weathering, UV, oils and many chemicals. See the Chemical Resistance Guide for further details.

APPLICATION:
Designed to be used with high temperature machine tool wiring. Ideal for outdoor installations in cold climates. This conduit is intended for installation in accordance with Article 350 of the NEC (ANSI/NFPA-70) and in section 14.5.4 of the ANSI/NFPA-79 Standard for Industrial Machinery:

  -Permitted for use in exposed or concealed locations.
  -Installations under raised floors in Data Processing Areas Article 645.5(D)(2)
  -Listed and marked for direct burial and in poured concrete.
  -For containment of 600 volts and lower potential circuits.
  -Permitted for Service Entrance wiring to 6 feet. Article 230.43
  -Sunlight resistant
  -Suitable as a grounding conductor when used for circuits rated up to 20A for the 3/8 & 1/2 inch grade sizes and 60A for the 3/4 thru 1-1/4 inch trade sizes in lengths six feet or less per NEC Article 250.118(7)
  -Installations in hazardous (classified) locations:
    Class I Div. 2 Article 501
    Class II Div. 1&2 Article 502
    Class III Div. 1&2 Article 503
  -Use as Feeders and Services at Marinas and Boatyards. Article 553.7(B)
  -Wiring on Building Article 225.10
  -Conductor Enclosers Adjacent to Motors over 600 V Article 430.223
  -Generator Installations Article 551.30
  -Underground Service, Feeder, Branch Circuit, and Recreational Vehicle Site Feeder Circuit Conductors Article 551.80
  -Elevators and Hoistways Article 620.21
  -Pools and Fountains Article 680

Listed File #E29278. Conforms to Underwriters Laboratories Standard ANSI/UL-360 for Liquidtight Flexible Steel conduit.

Certified File # LL18858. Conforms to CSA 22.2 No. 56 for use per the Canadian Electrical Code C22.1 Section 12-1300.

Tests Include:
WEEE and RoHS Compliant



STANDARD COLORS:
Machine Tool Gray.Other colors available upon request



WORKING TEMPERATURES:
U.L .-55°C to 105°C Air / 60°C Wet / 70°C Oil
CSA -50°C to 105°C Dry/75°C Oil

Flexibility:   See the Flexibility Comparison Guide

Metal Used: Steel

Plastic Used: PVC   See the Chemical Resistance Guide

High
Mech.
Strength

Listed
For
Direct
Burial

Halogen
Free

Low
Fire
Hazard

Accepts
Standard
Liquidtight
Fittings

Self
Extinquish

EMI/RFI
Shielding

Oil
Resistance

Acid
Resistance

X

X

 

 

X

X

 

X

X


® Electri-Flex Company 1-800-323-6174