Liquidtight Flexible Nonmetallic Conduit

TYPE - LNMP

Contact your local Sales Representative
Click Here for Printable Version

Inside
Diameter
Outside
Diameter
CartonReelReelList
Price
Trade
Size
TypeInside
Bend
Radius
Wt.
(Lbs.)/
100 Ft.
Min / MaxMin / MaxLengthPart #LengthPart #`LengthPart #Price Per
100 FT
3/8"LNM-P 102.5"16.485 / .505.755 / .7752508700250087003100087004$427.00
1/2"LNM-P 113.0"21.620 / .640.910 / .9302008710250087103100087104$549.00
3/4"LNM-P 124.0"31.815 / .8351.150 / 1.1701758720250087204--$780.00
1"LNM-P 136.0"421.030 / 1.0551.415 / 1.4401008730240087304--$979.00
1-1/4"LNM-P 147.0"611.370 / 1.3951.800 / 1.8251008740220087404--$1,317.00
1-1/2"LNM-P 158.0"791.585 / 1.6202.045 / 2.080508750215087504--$2,121.00
2"LNM-P 169.0"1202.045 / 2.0802.605 / 2.640508760210087604--$2,942.00


LNM-P TYPE A            
      
            



TYPE - LNMP
This nonmetallic liquidtight conduit is ideally suited for continuous flexing situations. It is often specified in "Power Track" or cable carrier installations and on industrial robots. It does not contain a metal core which could fatigue from repeated flexing or vibration.

CONSTRUCTION:
LNM-P is of the Layered, Type-A construction which incorporates a smooth seamless inner core of flexible PVC that is bonded to a covering of flexible PVC. Between these layers is a woven nylon mesh for added reinforcement. The PVC material is a high quality, flame-retardant compound which resists oils, mild acids and exposure to sunlight.

APPLICATION:
Type LNM-P is intended for installation in accordance with Article 356 of the NECŪ (ANSI/NFPA-70) for flexible liquidtight nonmetallic Conduit (LFNC-A or FNMC-A).
  -For containment of 600 volt and lower potential circuits.
  -Listed and Marked for Outdoor Use.
  -Installations in hazardous (classified) Locations:
    Class I Div. 2 Article 501
    Class II Div. 1& 2 Article 502
    Class III Div. 1 & 2 Article 503
  -Electric Signs and Outdoor Lighting over 1000 volts. Article 600.31(A)
  -Wiring methods for pools and spas. Article 680
Conforms to the requirements of Section 14.5.5 of the electrical Standard for Industrial Machinery NFPA-79.

Listed File # E 79308
Conforms to Underwriters Laboratories Standard ANSI/UL 1660 type A

Certified File #LL 18858
Conforms to CSA 22.2 No. 227.2 type A

Fittings:
Fittings for Layered Conduit are for that conduit only and are so identified by the marking "FNMC-A" or "LFNC-A" for Liquidtight Flexible Nonmetallic Conduit type A
1/2" straight examples include:

  - Thomas & Betts (Steel) #3721 (Plastic) #6302
  - Appleton Electric # STNM-50
  - Kellems / Hubbell # H050CNK

Tests Include:
WEEE and RoHS Compliant



Packaging:
Coiled in Cartons or in random lengths on Non-Returnable Reels.

STANDARD COLORS:
Safety Orange. Also available in Black and Gray.Other colors available upon request



WORKING TEMPERATURES:
-20° to 60°C

Flexibility:   See the Flexibility Comparison Guide

Plastic Used: PVC   See the Chemical Resistance Guide

High
Mech.
Strength

Listed
For
Direct
Burial

Halogen
Free

Low
Fire
Hazard

Accepts
Standard
Liquidtight
Fittings

Self
Extinquish

EMI/RFI
Shielding

Oil
Resistance

Acid
Resistance

 

 

 

 

 

X

 

X

X


® Electri-Flex Company 1-800-323-6174