Part of the CORRLOK® / Reiku Nylon System, as well as the Zero-Halogen product families.
CLFR is a Low Fire Hazard nonmetallic nylon corrugated Mechanical Protection Tubing (MPT) designed for the support and routing of conductors and cables.
Construction:
- Made from a specially compounded homogenous flame retardant, halogen-free nylon 6 material
- Self Extinguishing – Low Smoke – Low Toxicity
- Corrugated for flexibility and strength
- Resistant to alcohol, grease, mineral oil, diesel oil, weather, sunlight (UV), and more (consult factory for the full list)
Application:
- Intended to be used to interconnect separate component assemblies or consoles of electrical devices
- Railway / Public Transit
- Tunnels and Subways
- Wire Harnesses
Fittings:
Type CLFR is intended to be used only with the CF series of the CORRLOK® / Reiku System connectors and adapters.
Combustion & Flammability Properties
COMBUSTION & FLAMMABILITY |
TEST |
VALUE |
Vertical Burn (Material) | UL94 | V-0 Rating; No Flaming Drips |
Vertical Burn (Conduit) | UL360 | Pass; No Flaming Drips |
Flame Spread Index | ASTM E162 | 1.0; No Flaming Drips |
Smoke Generation (Flaming) | ASTM E662 (NFPA 258) | Ds [email protected] Min/Ds [email protected] Min |
Smoke Generation (Non-Flaming) | ASTM E662 (NFPA 258) | Ds [email protected] Min/Ds [email protected] Min |
Toxic Gas Generation | BOMBARDIER SMP 800-C | Pass |
*Test data is based on controlled laboratory conditions and does not necessarily reflect performance in actual fire conditions. Additional product information available upon request.
Markets:
Aerospace, Rail/Transit, Renewable Energy
Sizes 5/16″ through 1″ are Proudly Made in the USA