Part of the SHIELD-FLEX® family of EMI/RFI Shielding conduits, as well as Zero-Halogen product family.
Type HFSLA is identical to standard UL Listed liquidtight flexible steel conduit (See Type LA) but is augmented with a tinned copper shielding braid located over the inner steel core and under its protective Polyurethane jacket. The braid offers a minimum of 90% coverage.
Type HFSLA liquidtight flexible shielding conduit is designed for field installations where safety concerns exist regarding a material’s reaction in a fire situation. The specially formulated thermoplastic polyurethane jacket has excellent flame retardancy and low smoke characteristics. Acidic gases such as hydrogen chloride, hydrogen fluoride and hydrogen bromide are virtually eliminated as products of combustion.
Construction:
Inner Core:
- Hot Dipped Galvanized Steel
- 3/8” – 1-1/4” Squarelock Profile with continuous bonding strip
- 1-1/2” – 2” Fully Interlocked Profile
- Shielded with a tinned copper braid
Liquidtight Jacket:
- Low Smoke Zero-Halogen Thermoplastic
- Resistant to Ozone, Hydrocarbons, Moderate Chemicals and Oils
- Flame Retardant
- Low Smoke
- Low Toxicity
- Sunlight Resistant (UV)
Application:
- Meets ASTM E162 for Flame Spread
- Meets the requirements of Bombardier SMP 800-C for Toxic Gas Generation.
- Meets the requirements of ASTM E662 for Smoke Generation.
- NFPA130 approved
This conduit is intended for installation in accordance with Article 350 of the NEC (ANSI/NFPA-70)
- Suitable as an equipment grounding conductor per Article 250.118(6). Larger sizes require separate grounding conductor.
- Suitable for use in hazardous locations: Class I, Div. 2 and Classes II and III.
- PVC jacket is resistant to a wide variety of oils, acids, alkaline and ultraviolet light.
- Accepts Standard Metallic Liquidtight Fittings
- Designed for wiring applications requiring shielding effectiveness from Electromagnetic and Radio Frequency Interference (EMI/RFI)
HFSLA is a trademark of Electri-Flex Company, registered in the U.S. Patent and Trademark Office.
Combustion & Flammability Properties
COMBUSTION & FLAMMABILITY |
TEST |
| Vertical Burn (Material) | UL94 (V-0) |
| Vertical Burn (Conduit) | UL360 |
| Oxygen Index % | D2863 |
| Flame Spread Index | ASTM E162 |
| Smoke Generation (Flaming) | ASTM E662 (NFPA 258) |
| Smoke Generation (Non-Flaming) | ASTM E662 (NFPA 258) |
| Toxic Gas Generation | BOMBARDIER SMP 800-C |
| Toxicity Index | NES 713 |
* Test data is based on controlled laboratory conditions and does not necessarily reflect performance in actual fire conditions. Additional product information available upon request.
Markets:
Aerospace, DataComm, Defense, Healthcare, Ship Building, Telecommunications

All Products Proudly Made in the USA