Shield-Flex® EMI Shielded Conduit
Shield-Flex, by Electri-Flex Company, is a line of three EMI/RFI shielded conduit constructions, SLA, EMS and EMCS, built to protect sensitive electronic circuits from electromagnetic and radio frequency interference (EMI/RFI).
EMI/RFI shielded flexible conduit is a raceway built with a conductive shielding layer over a flexible steel or aluminum metal core. That shielding layer is important for EMI shielded conduit as it helps EMI shielding conduit to keep outside noise out of sensitive electronic circuits in communications, radar and data transmission work.
Shielded flexible conduit not only keeps interference out, but it also keeps emissions in, which is vital to meeting European CE standards, an important issue for OEMs. Shielding conduits also provide redundant EMI/RFI system protection when shielded cables run into EMI/RFI shielded enclosures.
Looking for the best EMI shielding conduit for data centers, military/defense, communications, shipbuilding, and other installations? The three Shield-Flex constructions below cover the range, along with low smoke zero-halogen (LSZH) jacketing product options.
Shielded Conduit Cost-Effective System Solution
Shield-Flex shields sensitive equipment and circuits from EMI/RFI emissions, both ingress and egress. Connector assemblies include a grounding ferrule that contacts the conduit’s internal metallic material with the connector body, producing a direct shield-to-drain (ground) path simply by tightening the connector. Its flexibility and simple assembly mean it takes less time to install. It uses off-the-shelf (OTS) connectors that are less expensive than high-end, mil-spec shielded conduit that require costly custom fittings.
Markets and Applications
Shield-Flex is ideal for the following Applications and Markets:
- Aerospace
- Air Handling Equipment (HVAC)
- CE – European EMI Requirements
- Commercial-off-the-shelf (COTS) (CAGE Code: 09641)
- Data Centers
- Defense/Military/Government
- Healthcare/Medical
- Industrial
- Radio Broadband/Antenna
- Ship Building
- Solar/Wind Energy
- Telecommunications
- Test & Measurement Equipment
- Transit
- Utilities
- Variable Speed Drives
- Wireless Communications
Three Levels of Shielding Effectiveness
With three levels of effectiveness to choose from, Shield-Flex can meet your needs.

Good Shielding: Type SLA is UL Listed, similar to standard Type LA liquidtight flexible steel conduit, but is augmented with a tinned copper shielding braid located over the inner steel core and under its protective PVC jacket. It has a working temperature range of -30°C to 80°C dry / 60°C wet /70°C oil, and the shielding braid offers a minimum of 90% shielding coverage.

Better Shielding: Type EMS offers a better shielding effectiveness than Type SLA and has a working temperature range of -55°C to 105°C. Type EMS has an inner core made from a fully interlocked bronze strip and does not contain a braided shield. An all-temperature PVC jacket is extruded over the core, resulting in a sealed, waterproof raceway when assembled with liquidtight fittings.
assembled with liquidtight fittings.

BEST Shielding: Type EMCS is a hybrid of SLA and EMS because it utilizes the same bronze core and PVC jacket as EMS but gets further screening protection from a tinned copper braid as found in the SLA product. Type EMCS offers the same working temperatures as EMS.
Halogen-Free (HF) Series: For a low-smoke, low-flame spread, zero-halogen version, ask for HFSLA, HFEMS, or HFEMCS. It’s ideal for field installation in confined, public areas such as subways, tunnels, etc. The jacketing material virtually eliminates the release of acidic gases found in PVC products.
*Shield-Flex, SLA, EMS, EMCS, HFSLA, HFEMS and HFEMCS are trademarks of Electri-Flex Company, registered in the U.S. Patent and Trademark Office.
The graph depicts a general comparative shielding effectiveness (attenuation in dBs) of all three types of SHIELD-FLEX conduit.
The dotted line indicates a comparison to standard unshielded liquidtight flexible conduit Type LA. The spectrum of test frequency is from 1 MHz to 10 MHz Electric Field, to 100 MHZ to 1 GHz Planewave Field and 2 GHz to 6 GHz Microwave Field. Tests were performed per MIL-STD-285 on 1″ trade size conduit using standard liquidtight fittings from Thomas & Betts series 5300. Results are based on controlled laboratory conditions and may vary in actual field installed conditions.
Frequently Asked Questions
What is EMI shielded conduit?
EMI shielded conduit is flexible conduit built with metallic shielding material that blocks electromagnetic and radio frequency interference from reaching the conductors inside. Our Shield-Flex line uses either a tinned copper braid, an interlocked bronze core, or both, so sensitive electronic circuits stay isolated from outside electrical noise.
What is the difference between EMI and RFI shielding?
RFI is the radio-frequency portion of the electromagnetic spectrum, so RFI shielding is part of EMI shielding rather than a separate thing. In practice, we treat them together, since the same shielding construction attenuates across a broad frequency range. Shield-Flex was tested per MIL-STD-285 across electric field, plane wave and microwave frequencies.
When do you need shielded conduit?
Choose shielded conduit when sensitive electronic circuits have to be protected from outside noise, as in radar installations, telecommunications and test and measurement equipment. It also contains emissions coming from inside the raceway, which matters for OEMs meeting European CE requirements, and it adds redundant protection alongside shielded cables and shielded enclosures.
What are the differences between SLA, EMS, and EMCS?
Type SLA has a steel core with a tinned copper braid, rated from -30°C up to 80°C dry, 60°C wet, and 70°C oil. Type EMS runs an interlocking bronze core with no braid, rated from -55°C up to 105°C. Type EMCS combines the bronze core and the copper braid for the best shielding.
Does shielded conduit require special fittings?
Usually not. Shield-Flex is designed around off-the-shelf liquidtight connectors, which cost less than the custom fittings high-end mil spec shielded conduit requires. The connector assembly carries a grounding ferrule that bridges the conduit's internal metallic material to the connector body, so tightening the connector creates a direct shield-to-drain path.
Is halogen-free shielded conduit available?
Yes. Every Shield-Flex construction has a halogen-free counterpart: HFSLA, HFEMS, and HFEMCS. The jacketing material is low-smoke and low-flame spread and virtually eliminates the acidic gases released by PVC products, which suits confined public spaces such as subways and tunnels.